Nexera Organic Acid Analysis System

Integrating Analytical Intelligence and Exceptional Instrument Performance

  • Описание
  • Features
  • Applications
  • Consumables

Описание

The Nexera Organic Acid Analysis System has been well-received in the fields of food and environment as a highly selective high-sensitivity system. It uses separation by ion exclusion chromatography and Shimadzu’s unique detection technique (pH-buffered electric conductivity detection). Recently, this system is being utilized by even more users in a wide variety of fields, and its usage in the fields of pharmaceuticals and life science is increasing.

Proprietary Detection Method

  • This system provides high selectivity and high sensitivity by using pH-buffered electric conductivity detection.

Ensures Highly Reliable Analysis Regardless of Operator Skill Level

  • Protects Expensive Columns:FlowPilot
  • Mobile Phase Levels Measured in Real Time
  • Auto-Diagnostics and Recovery
  • Automated Workflow

Features

Proprietary Detection Method
The organic acid system is a highly selective high-sensitivity system. In this system, organic acids are separated using ion exclusion chromatography via Shimadzu’s unique detection technique (pH-buffered electric conductivity detection). Then, a pH-buffering reagent is continuously added to the column eluate in order to keep the pH level at around neutral and dissociate organic acids in order to detect electric conductivity.

In ion exclusion mode, utilized in organic acid analysis, an H+ cation exchange resin is used as the filling agent. Organic acid, the target component, is separated by the magnitude of Donnan exclusion between the stationary phase surface of the H+ cation exchange group and the mobile phase. In this mode, because of the negative charge on the stationary phase, strong acids experience large electrostatic exclusion, and cannot permeate into the filling agent pores. With organic acids and other weak acids, however, the extent of permeation into the pores is determined by the size of this charge, producing a difference (separation) in elution times. Citric acid and lactic acid, which have a large negative charge (small pKa), experience more electrostatic exclusion than acetic acid, and are eluted faster. In principle, organic acids are all eluted up to the elution position for neutral substances (the position at which the pores are completely permeated), with elution ordered from smallest to largest pKa.

Ensures Highly Reliable Analysis Regardless of Operator Skill Level
Protects Expensive GPC Columns:
HPLC columns can be damaged by sudden pump starts and stops or extreme gradient changes. The Nexera automatically uses FlowPilot (Smart Flow Control) to increase the flow rate gradually to the set point. There is no need to create startup protocols for each analysis.

Simplifying Peak Integration: i-PeakFinder Automatic
Peak Integration Algorithm
If organic acids in samples such as alcoholic drinks are analyzed with an electric conductivity detector, negative peaks from the alcohol will be detected, increasing the peak integration processing time. Also, if peak integration is performed manually, not only will the process be labor-intensive, but there is a risk that the results will differ depending on the analyst. The i-PeakFinder algorithm was developed in response to these issues as an improvement on the traditional peak integration (Chromatopac mode). It reduces the complexity of peak integration as well as the risk of human error.

Mobile Phase Levels Measured in Real Time
Reservoir tray weight sensors (optional) can be used to monitor the volume of mobile phase or autosampler rinse solution in up to twelve containers. The containers can also be checked remotely from a smart device. You will no longer need to worry about running out of mobile phase mid-analysis, because the device will notify you before starting the run if the volume remaining is too low.

Auto-Diagnostics and Recovery
In rare cases, air bubbles can form in the mobile phase and cause problems if inhaled into the pump. The Nexera has the ability to monitor baseline changes and pressure fluctuations to check for abnormalities. When it detects an unusual fluctuation, it can automatically pause the analysis, purge the flow path, and restart analysis once it has confirmed recovery to normal pressure.

Automated Workflow
Automated support functions throughout the analytical workflow, from instrument startup to shutdown, significantly increases work efficiency. FlowPilot mobile phase flowrate control functionality is linked to column oven temperature, so that columns are protected during automatic column equilibration. Automatic checks for baseline drift maintain instrument stability even in unattended operation.

ANALYTICAL INTELLIGENCE

  • Automated support functions utilizing digital technology, such as M2M, IoT, and Artificial Intelligence (AI), that enable higher productivity and maximum reliability.
  • Allows a system to monitor and diagnose itself, handle any issues during data acquisition without user input, and automatically behave as if it were operated by an expert.
  • Supports the acquisition of high-quality, reproducible data regardless of an operator’s skill level for both routine and demanding applications.

Applications

Analysis of Organic Acid Counterions by Ion Exclusion Chromatography
The physicochemical and pharmacokinetic properties of active pharmaceutical ingredients change depending on the counterion used, and during drug development various counterions are tested to select the optimum salt. Residual inorganic impurities from catalysts or ions used during synthesis can also affect product solubility and stability, so it is extremely important that ion impurities are identified. We describe an example analysis that uses ion exclusion chromatography to increase separation selectivity for formic acid, acetic acid, fumaric acid, and maleic acid, which are organic acids frequently used for drug counterions.

Analysis of Organic Acids in Culture Medium Using Post-Column pH Buffering Organic Acid Analysis System
Organic acid analysis is often conducted using an ultraviolet absorbance detector. However, when analyzing media, which typically comprise complex matrices, the risk of contaminant components overlapping target components increases. Here, we introduce an example of analysis of organic acids in a culture medium using post-column pH buffered electrical conductivity detection in combination with a dual column oven, a system that provides both improved separation and high-selectivity detection.

Applying an Organic Acid Analysis System to Intestinal Flora Research
In recent years, it is becoming clear that intestinal flora in the gut contribute to the maintenance and preservation of the health of their hosts. Therefore, when examining the effects of intestinal flora on the host, the metabolites produced by intestinal flora can be considered to be related to these benefits. This article introduces an example of extracting metabolites produced by intestinal flora from mouse feces and measuring the short-chain fatty acids contained in the metabolites using an organic acid analysis system.

Consumables

Shim-pack SCR-102H

Column Particle
Size
(µm)
Dimensions
(I.D. x Length, mm)
P/N
Shim-pack
SCR-102H
7 8.0 x 300 228-17893-91
Guard Column
SCR-102H
10 6.0 x 50 228-17924-91